2200 Series / 2600 Series- General
Purpose Industrial Pressure Transducers
  • Gauge, Absolute, Vacuum and Compound Pressure Models
  • Submersible, General Purpose and Wash down Enclosures
  • High Stability Achieved by CVD Sensing Element
  • Millivolt, Voltage and Current Output Models

The 2200 series features stability and accuracy in a variety of enclosure options. The 2600 series extends the packaging options via an all welded stainless steel back end for demanding submersible and industrial applications. The 2200 and the 2600 feature proven CVD sensing technology, an ASIC (amplified units), and modular packaging to provide a sensor line that can easily accommodate specials while not sacrificing high performance.

Specifications

Input  
Pressure Range Vacuum to 400 bar (6000 psi)
Proof Pressure 2 x Full Scale (FS) (1.5 x Fs for 400 bar, >= 5000 psi)
Burst Pressure >35 x FS <= 6 bar (100 psi);
  >20 x FS >=60 bar (1000 psi);
  >5 x FS <= 400 bar (6000 psi)
Fatigue Life Designed for more than 100 million FS cycles
Performance  
Long Term Drift 0.2% FS/year (non-cumulative)
Accuracy 0.25 % FS typical (optional 0.15% FS)
Thermal Error 1.5% FS typical (optional 1% FS)
Compensated Temperatures -20° to 80° C (-5° to 180° F)
Operating Temperatures -40° to 125° C (-22° to 260° F) for elec. codes A, B, C, 1
  -20° to 80° C (-5° to 180° F) for elec. codes 2, D, G, 3
  -20° to 50° C (-5° to 125° F) for elec. codes F,M, P
  Amplified units >100°C maximum 24 Vdc supply
Zero Tolerance 1% of span
Span Tolerance 1% of span
Mechanical Configuration  
Pressure Port see ordering chart
Wetted Parts 17-4 PH Stainless Steel
Electrical Connection see ordering chart
Enclosure 316 ss, 17-4 PH ss
  IP65 for elec. codes A, B, C, D, G,1, 2, 3
  IP67 for elec. code “F”
  IP68 for elec. codes M, P
  IP30 for elec. code “3” with flying leads
Vibration 35g peak sinusoidal, 5 to 2000 Hz
Acceleration 100g steady acceleration in any direction 0.032% FS/g for 1 bar (15 psi) range decreasing logorithmically to 0.0007% FS/g for 400 bar (6000 psi) range.
Shock Withstands free fall to IEC 68-2-32 procedure 1
Approvals CE
Weight approx. 100 grams (additional cable; 75 g/m)


Individual Specifications

Millivolt Output units  
Output 100 mV +/- 1 mV
Supply Voltage(Vs) 10 Vdc (15 Vdc max.) Regulated
Bridge resistance 2600- 6000 ohms
Voltage Output units  
Output see ordering chart
Supply Voltage (Vs) 1.5 Vdc above span to 35 Vdc @ 6 mA
Supply Voltage Sensitivity 0.01% FS/ Volt
Min. Load Resistance (FS output / 2) Kohms
Current Consumption approx 6 mA at 7.5V output
Current Output units  
Output 4- 20 mA (2 wire)
Supply Voltage (Vs) 24 Vdc, (7- 35 Vdc)
Supply Voltage Sensitivity 0.01% FS/ Volt
Max. Loop Resistance (Vs- 7) x 50 ohms