| Input |
|
| Pressure
Range |
40 mbar to 6
bar (0.6- 87psi) |
| Proof
Pressure* |
35 bar for
40mbar range |
| |
50 bar for
160 mbar range |
| |
100 bar all
other ranges |
| Static
Pressure |
100 bar (1500
psi) |
| Performance |
|
| Output |
4- 20 mA (2
wire) |
| Supply
Voltage (Vs) |
8 to 30 Vdc
(8- 38 Vdc for IS units) |
| Supply
Voltage Sensitivity |
0.01% of max
span/ Volt |
| Zero
Stability |
0.2% of max
span per year non cumulative |
| Accuracy |
0.2% of max
span (typical) |
| Thermal
Error |
1.5% of max
span (typical) |
| Compensated
Temperatures |
-20° to
100° C (- 4° to 212° F) process |
| Operating
Temperatures |
-20° to
100° C (14° to 158° F) ambient |
| |
-10° to 70°
C (14° to 158° F) ambient |
| Response
Time |
0.1 seconds |
| Span
Adjustment |
25% to 100%
of max span |
| Max
Loop Resistance |
(Vs- 8) to 50
ohms |
|
| Mechanical
Configuration |
|
| Pressure
Port |
two G1/ 4
internal |
| Wetted
Parts |
Diaphragm 17-
7PH SS (optional 316 ss) |
| |
Flanges
carbon steel or 316SS |
| |
O- ring
Nitrile or Viton |
| Electrical
Connection |
M20 x 1.5mm,
screw terminals |
| Enclosure |
IP 65 (Nema
4) Aluminium alloy with anodized finish or
stainless steel, rotates 360° |
| Approvals |
CE, Intrinsic
Safety EExia II T6 (optional) |
| Weight |
4kg |
|