| Input |
|
| Pressure
Range |
4600, 1 bar
to 690 bar; 4610 10 to 10,000 psi |
| Proof
Pressure |
2 x Full
Scale (FS) for Stainless Steel Units |
| |
1.5 x FS for
Inconel Units |
| Burst
Pressure |
>35 x FS
<= 10 bar ranges |
| |
>15 x FS
<= 100 bar ranges |
| |
>8 FS
<= 690 bar ranges |
| Fatigue
Life |
3 million FS
cycles |
| Performance |
|
| Output |
4- 20 mA (2
wire) |
| Supply
Voltage (Vs) |
8 to 40 Vdc |
| Supply
Voltage Sensitivity |
0.005% of
max. span/ Volt |
| Long Term
Drift |
0.1% of max
span per year non- cumulative |
| Accuracy |
0.1 % FS
typical |
| Thermal
Error (typical) |
0.8% of max
span for performance code E |
| |
0.5% of max
span for performance code F |
| Compensated
Temperatures |
-25° to 75°
C (- 13° to 167° F) |
| Operating
Temperatures |
-25° to 85°
C (- 13° to 185° F) elec. conn. code C & G |
| |
-20° to 50°
C (- 4° to 122° F) elec. conn. code F |
| |
-30° to
100° C (- 22° to 212° F) process/ media |
| Zero
Tolerance |
0.1% FS,
typical |
| Span
Tolerance |
0.1% FS,
typical |
| Zero
Adjustment |
+/- 10% (100%
at factory) by potentiometer |
| Span
Adjustment |
25% to 125 %
of span by potentiometer |
| Max. Loop
Resistance |
(Vs- 8) x 50
ohms |