4000 Series- High Performance, Long Term Stability Pressure Transducers
  • Gauge, Sealed , Absolute, and Differential Pressure Models
  • Submersible, General Purpose and Weather Proof Enclosures
  • High Stability Achieved by Sputtered Sensing Element

The 4000 series provides exceptional levels of stability and other performance specifications in a wide variety of enclosures from submersible to differential styles. By using a sputtered sensing element, which achieves a molecular fusion of a strain gauge material, an insulating material, and the 17- 4 PH ss sensing element, the 4000 series provides the most stable sensor construction possible. These sputtered sensors are packaged for harsh applications requiring long term service where precise laboratory type measurements are required.

Also in the 4000 series is a range of high performance amplified sensors with voltage and current outputs. These laboratory specification sensors utilise the same thin film sensor as 4000. For more information contact your nearest sales office, a list of offices can be found at the back of this catalogue.

Specifications

Input  
Pressure Range 4000 series; 1 to 690 bar, 4010 series; 15 to 10,000 psi
Proof Pressure 2 x Full Scale (FS) (1.5 x FS for Inconel ports)
Burst Pressure >35 x Fs <= 10 bar (150 psi) ranges
  >15 x FS <= 100 bar (1500 psi) ranges
  >8 FS <= 690 bar (10,000 psi) ranges
Fatigue Life 3 million FS cycles
Common Line Pressure max. 60 bar absolute (850 psia) differential units only
Performance  
Output* 30mV +/- 1% (certificate supplied)
  (4010, 25 to 33 mV)
Supply Voltage (Vs) 10 Vdc Regulated (15 Vdc max)
Long Term Drift 0.06% per year non cumulative
Performance Code Accuracy Thermal Error
e typical typical
J 0.1 % span 1.2 % span
K 0.1 % span 0.6 % span
L 0.08 % span 0.6 % span
M 0.08 % span 0.3 % span
Compensated Temperatures -54° to 120 °C (- 65° to 250° F)
Operating Temperatures -54° to 135° C (- 65° to 275° F) for twist lock conn. “C”
  -54° to 120° C (- 65° to 250° F) for cable units “D”
  -20° to 50° C (- 4° to 122° F) for submersible unit “M”
Zero Tolerance 0 mV +/- 1 mV for performance codes J & K
  0 mV +/- 0.6 mV for performance codes L & M
Bridge Resistance 2200 to 5250 ohms
Mechanical Configuration  
Pressure Port see ordering chart
Wetted Parts 17- 4 PH ss (optional Inconel)
  [17- 4 PH and 15- 7 Mo Stainless Steel <= 1.6 bar (30 Psi)]
  Differential: dry non corrosive gas only on reference port
Electrical Connection see ordering chart
Enclosure 321 ss case
  IP40 for elec. Code “C” gauge datum
  IP65 for elec. Code “C” Absolute or Sealed Datum
  IP66 (weatherproof) for elec. code “D”
  IP68 (submersible) for elec. code “M”
Vibration 35g peak sinusoidal, 5 to 2000 Hz
Shock Withstands free fall to EIC 68- 2- 32 proc 1
Approvals CE
Weight 150 grams max (excluding cable)

Note: * Inconel 2.5bar (30 psi) range output is 25 mV +/- 1%