| Input |
|
| Pressure
Range |
6600, 0.5 to
400 bar; 6610 7.5 to 6,000 psi |
| Proof
Pressure |
2 x Full
Scale (FS) (1.5 x FS for 400 bar, >= 5000 psi)
|
| Burst
Pressure |
>35 x FS
<= 6 bar (100 psi); |
| |
>20 x FS
>= 60 bar (1000 psi); |
| |
>5 x FS
<= 400 bar (6000 psi) |
| Fatigue
Life |
Designed for
more than 100 million FS cycles |
| Performance
|
|
| Output |
4- 20 mA (2
wire) |
| Supply
Voltage (Vs) |
8 to 40 Vdc |
| Supply
Voltage Sensitivity |
0.005% of max
span/ Volt |
| Long Term
Drift |
0.15% of max
span/ year (non- cumulative) |
| Accuracy |
0.15 % FS
typical |
| Thermal
Error Typical |
-10° to 50°
C ( 15° to 120° F) 0.5% of max span |
| |
-20° to 80°
C (- 4° to 176° F) 1% of max span |
| Operating
Temperatures |
-20° to 85°
C (- 4° to 185° F) elec. conn. code C & G |
| |
-20° to 50°
C (- 4° to 122° F) elec conn code F |
| |
-30° to
100° C (- 22° to 212° F) process/ media |
| Zero
Tolerance |
0.1 % span,
typical |
| Span
Tolerance |
0.1% span,
typical |
| Zero
Adjustment |
+/- 10% (100%
at factory) by potentiometer |
| Span
Adjustment |
17% to 100 %
of span by potentiometer/ switches |
| Max. Loop
Resistance |
(Vs- 8) x 50
ohms |